JT Flanged Sight Flow Indicators in H₂S Service
- Kristen Modzelewski
- Apr 7
- 1 min read
The Problem:
In thermal oil production, especially in high-volume operations exceeding 200,000 bbl./day, the reliability of fuel gas injection systems is crucial. One thermal oil producer was relying on threaded rotameters to confirm gas flow at the wellhead, but encountered frequent clogging due to contaminated sour gas (H₂S). In addition to the plugging issues, the use of sour gas requires strict compliance with material standards for corrosion resistance.

The Clark-Reliance Solution:
We provided the customer with Jacoby-Tarbox® Flanged Bulls-Eye Flapper Sight Flow Indicators, designed specifically for this application. Features of these units include:
Flanged construction minimizes clogging and leakage risks
Wetted components built to NACE MR-01-75 / ISO15156-1 standards
Tempered borosilicate glass for visibility and durability
Full compliance with ASME B16.5, B16.24, and B16.1
Built in an ISO-9001 certified, automated facility
DID YOU KNOW? You can custom configure your own sight flow indicator or sight window with our Jacoby-Tarbox 3D Model Builder! This capability enhances the online digital experience for customers specifying JT products by enabling them to instantly find, configure and download 3-D models, data sheets and drawings for use within their designs.
Comments